SOP for Semi Automatic capsule filling machine
GENERAL REQUIREMENT:
1.1 The environment condition in which filling of hard
gelatin capsule should be normally carried out is:
Humidity:
Not more than 35% RH
Temperature: Not more than 25%
These
conditions should be maintain even work has stopped at the end of working day and during the week- ends.
1.2 The area around machine should be kept clean at all
times. Spillage should be cleaned up promptly.
The machine
must be thoroughly cleaned during the week –ends and when there is a product
change – over.
1.3 The speed gear should not be adjusted when the machine
is running on power,
1.4 Operator should wear rubber gloves, nose mask and head
covers when the machine is operated for filling.
PRELIMINARY OPERATIONS
2.1 The RH in the room or area
should be checked and recorded on manufacturing sheet. Filling should not be started
if humidity is more than 35%.
2.2 The compressed air supply
should be turned on and regulator set at about 5 psi.
2.3 The vacuum pump should be
turned on with vacuum hole blocked and the vacuum adjusted to not less than 600
mm Hg.
2.4 At a time on one container
each of the blended product to be filled and of the empty hard gelatin capsule should be brought into the
room and placed on either side of filling machine.
LOADING AND
RECTIFICATION
3.1 The setting of the loader and rectifier is checked by
rotating the machine manually with the clutch in the ON position and the
adjustments should be made.
3.2 The bag of empty capsule shells should be opened and
with a clean scoop, capsules should be loaded into the hopper of the
rectification assembly.
3.3 The capsule holding ring should be placed on the turn –
table and turned clock wise until it stops firmly against the drive pin.
3.4 The machine should be run manually to check if the
capsules enter the ring correctly. If not, the necessary adjustments should be
made.
3.5The main switch of the machine should be switched on and
the vacuum pump started. The vacuum should not be less than 600 mmHg.
3.6 The machine should be started
and the clutch lever moved to the right to bring the capsule loader into
action. It should be checked whether the capsules
are loaded properly. If the loading is satisfactory, the loading of the disc
should be completed.
3.7 As the last row of empty
capsules is deposited into the ring, on the turn – table should be stopped by
moving the clutch lever to the left.
3.8 The ring assembly should be
subjected to two or three revolutions on the turn- table in an anti clockwise
direction to provide the capsules additional exposure
to vacuum for effective separation of the bodies from the caps.
3.9 The ring assembly should be
removed from the table slowly taking care to avoid spilling the capsule; if
then be placed on the ring of the machine.
3.10 The top half of the ring
should be separated vertically and held chest high to see whether all the capsules have been separated , defective ones
should be rectified the hand and the bodies of such capsules should be positioned
inside the bottom hold of the ring if too
many capsules bodies are found
unseparated, the vacuum should be increased.
3.11 If the loading and
rectification of he capsules are satisfactory the process should be repeated
with another ring assembly.
FILLING OF POWDER
4.1 The bottom half of the ring
assembly should be placed on the left turntable near the drug hopper and
positioned.
4.2 The operator should run his
hand lightly over the ring to ensure that all the capsules arte below the ring
surface,
4.3 The speed of the turntable
should be adjusted to the pre-determined rate. This should not be adjusted
while the machine is running on power.
4.4 The drug hopper should be
filled with the powder up to the stirring arm.
4.5 The machine should be
switched on and the drug hopper pulled over the face of the moving ring until
the stirrer start moving and the powder fills the capsule bodies.
4.6 At the end of one revolution
of the ring should be pushed back smartly in order
to avoid double feeding of powder,
4.7 Excess powder from the
surface of the ring should be scraped off with a small PVX sheet or Teflon
scraper and the powder should be collected in the dust tray,
4.8 The body ring with the
capsules filled with powder should be removed and the cap ring placed on it and positioned so
that the two rings are joined.
SEALING OF CAPSULES
5.1 The pressure of the
compressed air supply should be checked and adjusted if necessary to between
5.5 kg/sq.cm to 6.5 kg/sq.cm. The air supply valve should be opened.
5.2 The sealing position should
be adjusted by means of a venire so that the sealed capsules co, ply with the
limits specified.
5.3 The complete ring assembly
containing the filled capsules should be lifted and held in a slightly inclined
position with the cap half facing the operator, and then positioned on the
joiner or sealing device.
5.4 The joiner plate should be
swung downwards into position and the ring assembly should be pulled snugly
against it.
5.5 The peg ring assembly should
be pulled, rotating if necessary to align the pins with the holes the peg pins
should be eased into the ring assembly until the capsule have started to join.
Note:-
Ø
The ring assembly must be kept firmly against
the joiner plate to prevent the capsules from being pushed before joining.
Ø
The ring assembly along with the joiner plate
should be held firmly and the air control foot pedal pressed in order to seal
the capsules with air pressure.
Ø
The ring assembly should be turned along with
the joiner plate by approximately 180o
and the pedal pressed again to repeat the sealing process.
Ø
The ring assembly should be pushed back
completely on to the peg ring in order to eject the capsules.
Ø
The capsules should be collected in a container
placed below the joiner.
Ø
The joiner plate should be swung upwards and the
ring assembly should be removed.
Ø
The ring should be removed and knocked against
the rubber bumper to remove excess powder.
Ø
The drug hopper rotary table should be cleaned
before repeating the filling cycle.
Ø
The weight of the filled capsules should be
determined and the weight of contents should bin adjusted, of necessary, by
altering the speed of the machine.
Ø
The capsules should be checked for proper
sealing and the necessary adjustments to the joiner plate, made, if required.
Ø
Machine adjustments should be made until the
weights are found to be within specified limits.
Ø
Capsule produced until these limits are reached
should be segregated and stored separately until they are taken up for
reprocessing.
CLEANING OF AUTOMATIC CAPSULE FILLING MACHINE
A.
PROCEDURE FOR PRODUCT TO
PRODUCT CHANGE OVER
Dedusting external surface – Use
a clean nylon brush and vacuum cleaner.
Dismantling- Remove
A. Filling and Loading turn-
tables
B. pusher slide
C. Rectifier, raceway with guide
block
D. Magazine
E. Drug hopper, auger and stirrer
F. Peg ring plate
G. Partial fill attachment
Ø
Collect all these parts in a suitable SS
container.
Ø
Cleaning of parts – clean the above parts by
washing with 0.1%Teepol solution and scrubbing with soft clean nylon brush.
Rinse with jet of potable water followed by rinsing with 5 micron filtered
water.
Ø
Cleaning of capsule plates-capsule plates are
soaked in hot 5 micron filtered water for 5-1min. The holes are cleaned using
0.1% Teepol solution. Rinse with jet of potable water by dipping in 5 micron
filtered water.
Ø
Cleaning of machine body- clean with 0.1% Teepol
solution and scrubbing with soft nylon brush. Clean with potable water.
Ø
Conforming effectiveness of cleaning- the DM
water rinse of product hopper and capsule plates is sent to QC department to
confirm absence of previous product.
Ø
Drying – the cleaned dried parts as mentioned in
step 2 are wiped and dried using a clean lint free duster. The capsule plate
has air-dried and stored in a SS trolley.
Ø
Assembling – Ressemble all the parts of machine
carefully checking for correctness of assembling and free motion of moving
parts. Replace the filter bag in the vacuum can below the machine with a clean
filter bag.
Note
Ø
Step 6 is a validatoty exercise to be conducted
once in six month at the time of product changeover.
Ø
Fix the cleaned tag with date, previous product
and initials.
Ø
Replace vacuum filter bag from vacuum can behind
machine every day at the start of filling.
B.
PROCEDURE FOR BATCH-TO-BATCH
CHANGEOVER
Ø
Remove powder below the powder-filling
turntable.
Ø
Dedust external surface of machine with vacuum
cleaner.
Ø
Dry clean the machine with clean lint free
duster.
Ø
Oil the different moving parts of machine on
loading side.
Ø
Dry clean the partial fill attachment by wiping
with a clean lint free duster.
C.PROCEDURE
TO BE FOLLOWED FOR CLEANING AT END OF SHIFT:
Ø
Remove empty capsule from capsule hopper.
Ø
Remove blend from powder hopper.
Ø
Dedust external surface with vacuum cleaner and
clean lint free duster.
Ø
Clean the capsule loading plate as per procedure
A step 4.
Ø
Clean the partial fill attachment as per
procedure A step 3.
Ø
Cover the machine with suitable cloth cover.
If machine is to be kept for, more than 2 days without
operation follow procedure B.